Part Number Hot Search : 
CSBUNG00 MC330 BTS120 LM336BAP MAX16 C1206 FM107 ZITE13F
Product Description
Full Text Search
 

To Download F-51553GNBJ-LW-AB Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 OPTREX
LCD Module Technical Specification 4U t
.
om c
First Edition
Oct 3, 2002
Final Revision
Type No.
w
w
w
.D
ta a
S F-51553GNBJ-LW-AB
Approved by (Production Div.) Checked by (Quality Assurance Div.)
h
ee
******
Checked by (ACI Engineering Div.)
Prepared by (Production Div.)
Table of Contents
1. General Specifications .................................................................................................................................. 2 2. Electrical Specifications ............................................................................................................................... 3 3. Optical Specifications ................................................................................................................................. 12 4. I/O Terminal.................................................................................................................................................... 14 5. Test................................................................................................................................................................... 17 6. Appearance Standards................................................................................................................................ 18 7. Code System of Production Lot............................................................................................................... 22 8. Type Number.................................................................................................................................................. 22 9. Applying Precautions .................................................................................................................................. 22 10. Precautions Relating Product Handling................................................................................................ 23 11. Warranty ........................................................................................................................................................ 24
Revision History
Rev. Date
w
w
w
.D
Page
t a
S a
e h
t e
U 4
.c
m o
Comment
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
w
w
w
.D
at
Sh a
et e
4U
.
om c
Page 1/24
1. General Specifications
Operating Temp. Storage Temp. Dot Pixels Dot Size Dot Pitch Viewing Area Outline Dimensions
: : : : : : :
min. -20C ~max. 70C min. -30C ~max. 85C 128 (W) *~ 64 (H) dots 0.48 (W) *~ 0.48 (H) mm 0.50 (W) *~ 0.50 (H) mm 66.8 (W) *~ 35.5 (H) mm 89.7 (W) *~49.8* (H) *~ 6.0 (D) mm * Without FPCUV 33.0g max. NTD-21558 ( STN / Blue-mode / Transmissive ) 6:00 8-bit parallel data transfer Serial data transfer LED Backlight / White Dimensional Outline UE-311234A
Weight LCD Type
: :
Viewing Angle Data Transfer
: :
Backlight Drawings
: :
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 2/24
2. Electrical Specifications
2.1. Absolute Maximum Ratings GND=0V Parameter Supply Voltage (Logic) Supply Voltage (Booster Circuit) Supply Voltage 1 (LCD Drive) Input Voltage Symbol VDD-GND VDD-GND V5,VOUT VIN Conditions Min. -0.3 -6.0 -18.0 -0.3 Max. 7.0 +0.3 +0.3 VDD+0.3 Units V V V V
2.2. DC Characteristics Ta=25C, GND=0V Parameter Supply Voltage (Logic) Supply Voltage (LCD Drive) "High" Level Input Voltage "Low" Level Input Voltage "High" Level Output Voltage "Low" Level Output Voltage Supply Current Symbol VDD-GND VDD-V5 VIH VIL VOH VOL IDD IOH=-0.1mA IOL=0.1mA VDD-GND=5.0V Conditions With Triple Min. 4.5 Typ. Max. 5.5 Units V V 0.84 VDD 0.2*~ VDD VDD 0.2*~ VDD 1.26 V V V V mA
Shown in 3.1 0.8*~ VDD GND 0.8*~ VDD GND -
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 3/24
2.3. AC Characteristics 2.3.1. Read/Write Operation Sequence (80 series CPU) VDD=5.0V10% Parameter Address Setup Time Address Hold Time System Cycle Time Control Low Pulse Width WRITE READ Control High Pulse Width WRITE READ Data Setup Time Data Hold Time RD Access Time Output Disable Time Symbol Min. 0 0 166 30 70 30 30 30 10 5 Max. 70 50 Units ns ns ns ns ns ns ns ns ns ns ns
tAW8 tAH8 tCYC8 tCCLW tCCLR tCCHW tCCHR tDS8 tDH8 tACC8 tOH8
tAH8 A0
CS1 (CS2="1") tAW8 tCCLR, tCCLW WR, RD tf D0~D7 (WRITE) tACC8 D0~D7 (READ) tOH8 tDS8 tr tCCHR, tCCHW tDH8 tCYC8
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 4/24
2.3.2. Read/Write Operation Sequence (68 series CPU) VDD=5.0V10% Parameter Address Setup Time Address Hold Time System Cycle Time Data Setup Time Data Hold Time Access Time (CL=100pF) Output Disable Time Enable High Pulse Width READ WRITE Enable Low Pulse Width READ WRITE Symbol Min. 0 0 166 30 10 10 70 30 30 30 Max. 70 50 Units ns ns ns ns ns ns ns ns ns ns ns
tAH6 tAW6 tCYC6 tDS6 tDH6 tACC6 tOH6 tEWHR tEWHW tEWLR tEWLW
CS1 (CS2="1") tCYC6 tEWLR, tEWLW
E
tEWHR, tEWHW tAW6 tr tf tAH6
A0,WR,RD tDS6 D0D7 (WRITE) tACC6 D0D7 (READ) tOH6 tDH6
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 5/24
2.3.3. Serial Interface Sequence VDD=5.010% Parameter Serial Clock Cycle Time Serial Clock High Pulse Width Serial Clock Low Pulse Width Address Setup Time Address Hold Time Data Setup Time Data Hold Time Chip Select Setup Time Chip Select Hold Time Symbol Min. 200 75 75 50 100 50 50 100 100 Max. Units ns ns ns ns ns ns ns ns ns
tSCYC tSHW tSLW tSAS tSAH tSDS tSDH tCSS tCSH
tCSS CS1 (CS2="1") tSAS A0 tSCYC tSLW SCL tf tSDS tr tSAH
tCSH
t SHW tSDH
SI
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 6/24
2.3.4. Display Control Timing Characteristics Reset Input Timing Parameter Reset time Reset "L" Pulse Width Output Timing Parameter FR Delay Time Symbol Min. Typ. 10 Max. 40 Symbol Min. 0.5 Typ. Max. 0.5 VDD=5.010% Units s
tR tRW
VDD=5.010% Units ns
tDFR
Note 1 :Valid only when the master mode is selected. Note 2:All timing is based on 20% and 80% of Vss.
RES
t RW
Internal states During reset
tR
Reset complete
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 7/24
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 8/24
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 9/24
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 10/24
2.4. Lighting Specifications 2.4.1. Absolute Maximum Ratings Ta=25C (1Unit) Parameter Foward Current Reverse Voltage LED Power Dissipation Symbol IF VR PD Conditions Note 1 Min. Typ. Max. 75 8 0.375 Units mA V W
Note 1 : Refer to the foward current derating curve.
IF (mA) 75
30
-20
25
70
Ta (C)
*{ ANODE
*| CATHODE
2.4.2. Operating Characteristics Ta=25C Parameter Foward Voltage Luminance of Backlight Surface Symbol VF L Conditions IF=40mA IF=40mA Min. 65 Typ. 5.0 100 Max. Units V cd/m2
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 11/24
3. Optical Specifications
3.1. LCD Driving Voltage Parameter Recommended LCD Driving Voltage Note 1 VDD-V5 Symbol Conditions Ta= -20C Ta=25C Ta=70C Min. 7.8 7.4 Typ. 8.5 Max. 9.1 9.1 Units V V V
Note 1 : Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and response time are not guaranteed over the entire range. 3.2. Optical Characteristics Ta=25C, 1/65 Duty, 1/7 Bias, VOD=8.5V (Note 4), = 0, = - Parameter Contrast Ratio Viewing Angle Response Time Rise Note 2 Decay Note 3 TON TOFF Note 1 Symbol CR Conditions = 0, = - Min. Typ. 8 Max. Units
Shown in 3.3 160 190 240 290 ms ms
Note 1 :Contrast ratio is definded as follows. (CR = LON / LOFF) LON : Luminance of the ON segments LOFF: Luminance of the OFF segments Mesuring Spot : 3mm Note 2 :The time that the luminance level reaches 90% of the saturation level from 0% when ON signal is applied. Note 3 :The time that the luminance level reaches 10% of the saturation level from 100% when OFF signal is applied. Note 4 :Definition of Driving Voltage VOD VOD=VCC-VADJ-VBE Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias (A: Duty Number, B: Bias Number). Driving voltage VOD is definded as the voltage VO-P when the contrast ratio (CR=LON / LOFF) is at its maximum.
VO-P
( B-2 )x VO-P / B 1/ ( f F xA ) 1 / fF


F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 12/24
3.3. Definition of Viewing Angle and Optimum Viewing Area *Point * shows the point where contrast ratio is measured. : = 0, = - *Driving condition: 1/65 Duty, 1/7 Bias, VOD=8.5V, fF=84.6Hz
90 135 45
180 ( = 0)
90
10 20 30 40 50
180
0
225 270
315 270
*Area
shows typ. CR3 (Mesuring Spot : 3mm)
3.4. System Block Diagram
Temperature Chamber Rotation Table ( , ) Photometer #1980A WB
LCD Optical Fiber
Computer
Control Unit & Waveform Generator Halogen bulb
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 13/24
4. I/O Terminal
4.1. Pin Assignment CN1 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Symbol CS1 RES A0 WR RD D0 D1 D2 D3 D4 D5 D6 D7 VDD GND VOUT CAP3CAP1+ CAP1CAP2CAP2+ V1 V2 V3 V4 V5 VR C86 P/S IRS Chip Select Signal L : Active Reset Signal L : Reset H : D0~D7 are Display Data L : D0~D7 are Instructions Write Signal L : Active Read Signal L : Active Data Bus Line Data Bus Line Data Bus Line Data Bus Line Data Bus Line Data Bus Line Data Bus Line Data Bus Line Power Supply for Logic Power Supply ( 0V, GND ) DC/DC Voltage Converter Output DC/DC Voltage Converter Negative Connection DC/DC Voltage Converter Positive Connection DC/DC Voltage Converter Negative Connection DC/DC Voltage Converter Negative Connection DC/DC Voltage Converter Positive Connection Power Supply for LCD Drive V1 = 1/7,V5 Power Supply for LCD Drive V2 = 2/7,V5 Power Supply for LCD Drive V3 = 5/7,V5 Power Supply for LCD Drive V4 = 6/7,V5 Power Supply for LCD Drive V5,VOUT Voltage Adjustment Pin Interface Mode Select Signal H : 68 series L : 80 series Parallel / Serial Data Select Signal H: Parallel L: Serial Function
This terminal selects the resistors for the V5 voltage level adjustment. IRS="H" :Use the internal resistors IRS="H" :Do not use the internal resistors. The V5 voltage level is requlated by an external resistive voltage divider attached to the VR terminal.
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 14/24
4.2. Example of Power Supply
MODULE
VDD GND C1
VDD GND VOUT CAP3Booster Circuit
LSI
C2 C3
CAP1+ CAP1CAP2CAP2+
C4
C5 C6 C7 C8
V1 V2 V3 V4 V5 R2 LCD Driver
C9
R1 VR
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 15/24
4.3.Block Diagram
CS1 RES A0 WR RD D0 D1
COM 32
D2
D3 D4 Control LSI D5 D6 D7 VDD GND VOUT CAP3CAP1+ CAP1CAP2CAP2+ V1 V2 V3 V4 V5 VR C86 P/S IRS S1D15605 D11B000
COM 32 SEG 128
LCDP 128 x 64 dots
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 16/24
5. Test
No change on display and in operation under the following test condition. Conditions: Unless otherwise specified, tests will be conducted under the following condition. Temperature: 205C Humidity : 655%RH tests will be not conducted under functioning state. Parameter High Temperature Operating Low Temperature Operating High Temperature Storage Low Temperature Storage Damp Proof Test Temperature Cycle Test Conditions 70C2C, 96hrs (operation state) -20C2C, 96hrs (operation state) 85C2C, 96hrs -30C2C, 96hrs 40C2C,90~95%RH, 96hrs 5 Cycle
70 C 25 C -20C
30Min 10Min 30Min 10Min 1 Cycle
No. 1 2 3 4 5 6
Notes
1 2 1,2 1,2 1
The function test shall be conducted after 1 hours storage at the normal temperature and humidity after removed from the test chamber. 7 Shock Test To be measured after dropping from 60cm high on the concrete surface in packing state.
Dropping method corner dropping F E B 60cm Concrete Surface G D A C A corner : once Edge dropping B,C,D edge : once Face dropping E,F,G face : once
Note 1 :No dew condensation to be observed. Note 2 :The function test shall be conducted after 4 hours storage at the normal Temperature and humidity after removed from the test chamber. Note 3 :Vibration test will be conducted to the product itself without putting it in a container.
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 17/24
6. Appearance Standards
6.1. Inspection conditions The LCD shall be inspected under 40W white fluorescent light. The distance between the eyes and the sample shall be more than 30cm. All directions for inspecting the sample should be within 45against perpendicular line.
45
6.2. Definition of applicable Zones
X
X
X
A Zone B Zone X C Zone X : Maximum Seal Line
A Zone : Active display area B Zone : Out of active display area ~ Maximum seal line C Zone : Rest parts A Zone + B Zone = Validity viewing area
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 18/24
6.3. Standards(middle scale, LED) D = ( Long + Short ) / 2 No. 1 Parameter The Shape of Dot (1) Pin Hole Dimension D 0.10 0.10 < D 0.20 Acceptable Number * 1 pc / dot(only segment)or less 5 pcs / cell or less Criteria * : Disregard Units : mm
(2) Pattern Shift A B | A - B | 0.15
(3) Breakage or Chips / Deformation A 1.Segment Type Dimension A 0.10 B 0.15 B 2.Dot Type Dimension A A0.10 Acceptable Number * (Should not be connected to next dot) 1 pc / dot(only segment)or less B 0.103.Defective type extends over multiple numbers of dots Dimension D0.10 Acceptable Number * 1 pc / dot(only segment)or less 0.10F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 19/24
D = ( Long + Short ) / 2 No. 2 Parameter Black and White Spots, Foreign Substances Dimension D 0.10 0.10< D 0.20 0.20< D 0.30 (1) Round Shape Zone A * 6 4 Criteria
* : Disregard Units : mm
Acceptable Number B * 6 4 C * * *
Individual dot must secure 1/2 area or more.
(2) Line Shape Zone Length * L 2.0 L 1.0 * 0.10In the same way (1)
No more than 9pcs as total. (Refer to "Complex Foreign Substance Defects")
3
Color Variation Air Bubbles (between glass & polarizer)
Not to be conspicuous defects.
4
Zone Dimension D 0.30 0.30< D 0.40 0.40< D 0.60 No more than 3pcs as total. A * 3 2
Acceptable Number B * * 3 C * * *
(Refer to "Complex Foreign Substance Defects")
5 6
Polarizer Scratches Polarizer Dirts
Not to be conspicuous defects. If the stains are removed easily from LCDP surface, the module is not defective.
7
Complex Foreign Substance Defects
Black spots, line shaped foreign substances or air bubbles between glass & polarizer should be 9pcs maximum in total. 20mm or more
8
Distance between Different Foreign Substance Defects
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 20/24
D = ( Long + Short ) / 2 No. 11 Parameter Chipped Glass Criteria
* : Disregard Units : mm
(1) Other than electrode pad areas and corner areas
Y Z t X
X 10.0
Y 1.5
Z t
(2) Corner Areas 1.Lead Areas
X Y Y t
Z
X
X Half dimension till first Leads terminal
Y Same as terminal width
Z *
It is allowed 1 chip as total length of Z sirection In case of 2 or more chips, Z 1/2t
2.Other than electrode pad Areas
X
Y
X+Y8.0
If the chipped area touches the seal line, the LCD is not acceptable.
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 21/24
7. Code System of Production Lot
The production lot of module is specified some of the following.
Factory Number (Numeral) Factory Code (Alphabet) Production Week (1~5) Production Month (1~9, X, Y, Z) Production Year (Lower 2 digits)
Factory Number (Numeral) Production Day of the Week (Sun : A Mon : B~) Factory Code Production Week (1~5) Production Month (1~9, X, Y, Z) Production Year (Lower 2 digits)
8. Type Number
The type number of module is specified as follows. F-51553GNBJ-LW-AB
9. Applying Precautions
Please contact us when questions and/or new problems not specified in this Specifications arise.
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 22/24
10. Precautions Relating Product Handling
The Following precautions will guide you in handling our product correctly. 1) Liquid crystal display devices 1. The liquid crystal display device panel used in the liquid crystal display module is made of plate glass. Avoid any strong mechanical shock. Should the glass break handle it with care. 2. The polarizer adhering to the surface of the LCD is made of a soft material. Guard against scratching it. 2) Care of the liquid crystal display module against static electricity discharge. 1. When working with the module, be sure to ground your body and any electrical equipment you may be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work tables against the hazards of electrical shock. 2. Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other conductivity-treated fibers. 3. Slowly and carefully remove the protective film from the LCD module, since this operation can generate static electricity. 3) When the LCD module alone must be stored for long periods of time: 1. Protect the modules from high temperature and humidity. 2. Keep the modules out of direct sunlight or direct exposure to ultraviolet rays. 3. Protect the modules from excessive external forces. 4) Use the module with a power supply that is equipped with an overcurrent protector circuit,since the module is not provided with this protective feature. 5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands or clothing come in contact with LCD fluid, wash immediately with soap. 6) Conductivity is not guaranteed for models that use metal holders where solder connections between the metal holder and the PCB are not used. Please contact us to discuss appropriate ways to assure conductivity. 7) For models which use CFL: 1. High voltage of 1000V or greater is applied to the CFL cable connector area. Care should be taken not to touch connection areas to avoid burns. 2. Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn. 3. The use of CFLs for extended periods of time at low temperatures will significantly shorten their service life. 8) For models which use touch panels: 1. Do not stack up modules since they can be damaged by components on neighboring modules. 2. Do not place heavy objects on top of the product. This could cause glass breakage. 9) For models which use COG,TAB,or COF: 1. The mechanical strength of the product is low since the IC chip faces out unprotected from the rear. Be sure to protect the rear of the IC chip from external forces. 2. Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical damage, avoid installation configurations in which the rear of the IC chip runs the risk of making any electrical contact.
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 23/24
10) Models which use flexible cable, heat seal, or TAB: 1. In order to maintain reliability, do not touch or hold by the connector area. 2. Avoid any bending, pulling, or other excessive force, which can result in broken connections. 11) have an adverse effect on connecting parts ( LCD panel-TCP / HEAT SEAL / FPC / etc., PCB-TCP / HEAT SEAL / FPC etc., TCP-HEAT SEAL, TCP-FPC, HEAT SEAL-FPC, etc.,) depending on its materials. Please check and evaluate these materials carefully before use. In case of acrylic plate is attached to front side of LCD panel, cloudiness ( very small cracks ) can occur on acrylic plate, being influenced by some components generated from polarizer film.. Please check and evaluate those acrylic materials carefully before use.
12)
11. Warranty
This product has been manufactured to your company's specifications as a part for use in your company's general electronic products. It is guaranteed to perform according to delivery specifications. For any other use apart from general electronic equipment, we cannot take responsibility if the product is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. If the product is to be used in any of the above applications, we will need to enter into a separate product liability agreement. 1. We cannot accept responsibility for any defect, which may arise from additional manufacturing of the product (including disassembly and reassembly), after product delivery. 2. We cannot accept responsibility for any defect, which may arise after the application of strong external force to the product. 3. We cannot accept responsibility for any defect, which may arise due to the application of static electricity after the product has passed your company's acceptance inspection procedures. 4. When the product is in CFL models, CFL service life and brightness will vary According to the performance of the inverter used, leaks, etc. We cannot accept responsibility for product performance, reliability, or defect, which may arise. 5. We cannot accept responsibility for intellectual property of a third party, which may arise through the application of our product to your assembly with exception to those issues relating directly to the structure or method of manufacturing of our product. 6. Optrex will not be held responsible for any quality guarantee issue for defect products judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe, Display LC delivery which ever comes later.
F-51553GNBJ-LW-AB (AB) No. 2002-0243
OPTREX CORPORATION
Page 24/24


▲Up To Search▲   

 
Price & Availability of F-51553GNBJ-LW-AB

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X